Goodman
10 kW Electric Heat Kit
Goodman 208/240V, 1-Phase, No Breaker, For air handlers (AHVE/AMVE/AMVT/AMST/AWST), Current-Gen | HKTSN10X1
The right accessory completes an installation and keeps a system running the way it should. This is where you'll find the supporting components — electric heat kits that add backup or primary heat, modular blowers, and the accessory parts that go with furnaces, air handlers, coils, and packaged units.
215 products
Goodman
Goodman 208/240V, 1-Phase, No Breaker, For air handlers (AHVE/AMVE/AMVT/AMST/AWST), Current-Gen | HKTSN10X1
Goodman
Goodman 208/240V, 1-Phase, No Breaker, For air handlers (ARUF-SF/ARPT/AVPTC), Legacy Series | HKSX10XC
Goodman
Goodman 208/240V, 1-Phase, No Breaker, For air handlers & packaged units (ARUF), Legacy Series | HKR-10
Goodman
Goodman 208/240V, 1-Phase, No Breaker, For modular blowers / electric furnaces (MBR/MBVC), Current-Gen | HKTAN101
Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, For air handlers (AHVE/AMVE/AMVT/AMST/AWST), Current-Gen | HKTSD10X1
Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, For air handlers (ARUF-SF/ARPT/AVPTC), Legacy Series | HKSC10XC
Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, For air handlers & packaged units (ARUF), Legacy Series | HKR-10C
Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, For modular blowers / electric furnaces (MBR/MBVC), Current-Gen | HKTAD101
Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, For packaged AC/HP units (GPC/GPH), Current-Gen | HKTPD101

Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, For packaged units (GPC/GPH), Legacy Series | HKP-10C

Trane
Trane 240V, Three-Phase, for Packaged Units | BAYHTRG310A

Trane
Trane 480V, Three-Phase, for Packaged Units | BAYHTRG410A

Trane
Trane Circuit Breaker, for 5TMM5 | BAYHTRA510BRK
Trane
Trane Circuit Breaker, for GAM5, TAM9, TAMX | BAYEAAC10BK1B
Trane
Trane Circuit Breaker, for New Hyperion Cabinet Widths | BAYEA1310BK1A
Trane
Trane Circuit Breaker, for TEM | BAYHTR1510BRK
Trane
Trane for Packaged Units | BAYHTRG110A

Trane
Trane Large Cabinet, for 5TEM7D & 5TEM9D | EH10-MPA-LB
Trane
Trane Lug, for GAM5, TAM9, TAMX | BAYEAAC10LG1B
Trane
Trane Lug, for Hyperion, for New Hyperion Cabinet Widths | BAYEA1310LG1A
Trane
Trane Lug, for TEM | BAYHTR1510LUG
Trane
Trane Lug, Three-Phase | BAYHTR3510LUG
Trane
Trane Medium Cabinet, for 5TEM7C04 | EH10-SVZ-M
Trane
Trane Medium Cabinet, for 5TEM9C02 | EH10-MPA-MB

Trane
Trane Three-Phase | BAYHTRV310F

Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, Current-Gen | HKTZD15X1
Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, For air handlers (ARUF) only, Legacy Series | HKA-15C
Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, For modular blowers / electric furnaces (MBR/MBVC), Current-Gen | HKTAD151

Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, For packaged AC/HP units (GPC/GPH), Current-Gen | HKTPD151
Goodman
Goodman 208/240V, 1-Phase, With Circuit Breaker, For packaged units (GPC/GPH), Legacy Series | HKP-15C

Goodman
Goodman 208/240V, 3-Phase, No Breaker, For air handlers (AHVE/AMVE/AMVT/AMST/AWST), Current-Gen | HKTSN15X3
Goodman
Goodman 208/240V, 3-Phase, No Breaker, For air handlers & packaged units, Legacy Series | HKR3-15
Goodman
Goodman 208/240V, 3-Phase, With Circuit Breaker, For air handlers (AHVE/AMVE/AMVT/AMST/AWST), Current-Gen | HKTSD15X3
Goodman
Goodman 208V, 1-Phase, With Circuit Breaker, For air handlers (AHVE/AMVE/AMVT/AMST/AWST), Current-Gen | HKTSD15XA
Goodman
Goodman 208V, 1-Phase, With Circuit Breaker, For air handlers (ARUF-SF/ARPT/AVPTC), Legacy Series | HKSC15XA
Goodman
Goodman 240V, 1-Phase, With Circuit Breaker, For air handlers (AHVE/AMVE/AMVT/AMST/AWST), Current-Gen | HKTSD15XB
Goodman
Goodman 240V, 1-Phase, With Circuit Breaker, For air handlers (ARUF-SF/ARPT/AVPTC), Legacy Series | HKSC15XB

Trane
Trane 240V, Three-Phase, for Packaged Units | BAYHTRG315A

Trane
Trane 480V, Three-Phase, for Packaged Units | BAYHTRG415A
Trane
Trane Circuit Breaker, for GAM5, TAM9, TAMX | BAYEABC15BK1B
Most parts and accessories are matched to a specific piece of equipment or a specific job, so the key is compatibility. Know the system or model you're outfitting, then pick the accessory built for it.
Looking for a specific part or heat kit? Tell us your model and we'll help you find it →
It's a set of electric resistance heating elements that install in an air handler to add heat — either as backup (auxiliary) heat for a heat pump or as the primary heat in an all-electric system. They're sized in kilowatts (kW).
Heat-kit sizing depends on your air handler's capacity, your electrical service, and how much backup or primary heat you need. Larger kits draw more power, so the breaker and wiring must support them — match the kit to both the air handler and the panel.
A modular blower is a standalone blower section used to build an air handler — commonly paired with a cased coil and, optionally, a heat kit — giving a flexible indoor unit when a packaged air handler doesn't fit the application.
Mostly no. Heat kits, blowers, and accessory parts are matched to specific equipment families and capacities. Check that any part is compatible with your exact model before ordering.
If you don't see the exact accessory or replacement part for your equipment, reach out with the model number and we'll help you track down the right one.