Goodman
2.5 Ton Packaged AC
Goodman 13.4 SEER2, Dedicated Horizontal, R-32 | GPCH33031
A packaged air conditioner puts the whole cooling system in one outdoor cabinet on a roof or ground pad — no indoor equipment needed. It suits slab-built homes and light commercial buildings. Browse by tonnage from 2 to 5 tons.
30 products
Goodman
Goodman 13.4 SEER2, Dedicated Horizontal, R-32 | GPCH33031
Goodman
Goodman 13.4 SEER2, Multi-Position, R-32 | GPCM33031
Ruud
Ruud 13.4 SEER2, Dedicated Horizontal, R-454B | RACBYB030AJT000NA
Ruud
Ruud 13.4 SEER2, Downflow/Convertible, R-454B | RACAYB030AJT000NA
Trane
Trane 14.0 SEER2, Single-Stage, R-454B | 5TCC4030A1000
Goodman
Goodman 13.4 SEER2, Dedicated Horizontal, R-32 | GPCH32431
Goodman
Goodman 13.4 SEER2, Multi-Position, R-32 | GPCM32431
Ruud
Ruud 13.4 SEER2, Dedicated Horizontal, R-454B | RACBYB024AJT000NA
Ruud
Ruud 13.4 SEER2, Downflow/Convertible, R-454B | RACAYB024AJT000NA
Trane
Trane 14.3 SEER2, Single-Stage, R-454B | 5TCC4024A1000
Goodman
Goodman 13.4 SEER2, Dedicated Horizontal, R-32 | GPCH34231
Goodman
Goodman 13.4 SEER2, Multi-Position, R-32 | GPCM34231
Ruud
Ruud 13.4 SEER2, Dedicated Horizontal, R-454B | RACBYB042AJT000NA
Ruud
Ruud 13.4 SEER2, Downflow/Convertible, R-454B | RACAYB042AJT000NA
Trane
Trane 13.8 SEER2, Single-Stage, R-454B | 5TCC4042A1000
Goodman
Goodman 13.4 SEER2, Dedicated Horizontal, R-32 | GPCH33631
Goodman
Goodman 13.4 SEER2, Multi-Position, R-32 | GPCM33631
Ruud
Ruud 13.4 SEER2, Dedicated Horizontal, R-454B | RACBYB036AJT000NA
Ruud
Ruud 13.4 SEER2, Downflow/Convertible, R-454B | RACAYB036AJT000NA
Trane
Trane 13.8 SEER2, Single-Stage, R-454B | 5TCC4036A1000
Goodman
Goodman 13.4 SEER2, Dedicated Horizontal, R-32 | GPCH34831
Goodman
Goodman 13.4 SEER2, Multi-Position, R-32 | GPCM34831
Ruud
Ruud 13.4 SEER2, Dedicated Horizontal, R-454B | RACBYB048AJT000NA
Ruud
Ruud 13.4 SEER2, Downflow/Convertible, R-454B | RACAYB048AJT000NA
Trane
Trane 13.4 SEER2, Single-Stage, R-454B | 5TCC4048A1000
Goodman
Goodman 13.4 SEER2, Dedicated Horizontal, R-32 | GPCH36031
Goodman
Goodman 13.4 SEER2, Multi-Position, R-32 | GPCM36031
Ruud
Ruud 13.4 SEER2, Dedicated Horizontal, R-454B | RACBYB060AJT000NA
Ruud
Ruud 13.4 SEER2, Downflow/Convertible, R-454B | RACAYB060AJT000NA
Trane
Trane 13.4 SEER2, Single-Stage, R-454B | 5TCC4060A1000
When there's no basement or attic for a split system's indoor unit, a packaged AC solves it by combining everything outdoors. Many accept an electric heat strip for mild-winter heating, and installation is simpler because the whole system ships in one cabinet.
Have a question about the right fit for your setup? Reach out and we'll help →
When there's no indoor space for equipment — slab homes without a basement or attic, or light-commercial rooftops. Everything is combined in one outdoor cabinet.
On its own it cools, but most accept an electric heat strip for mild-winter heat. For real cold, choose a packaged heat pump or gas/electric unit.